Powerware 9315 UPS 625 to 750kVA Technical Specs

625 to 750 kVA

bullet9315-625/625 - 625kVA/500kW
bullet9315-750/750 - 750kVA/600kW
To Product Page
Model Selection Guide

Input

Voltage Range

 +10% to -15%

Frequency Range

+/-5%

Surge Protection

 Meets ANSI C62.41, Category A & B, EN 50091-2 and EN 50082-2

Power Factor 0.95 Typical at full load with input filter

Output

Voltage Regulation

Better than +/- 1%

Voltage THD

 Less than 5% (100% nonlinear load); Less than 3% (100% linear load)

Transient Response

 Less than 5% for 100% load, step full recovery within 1 cycle

Frequency Regulation(Free Run) +/- 0.005 Hz
Frequency Sync Range+/- 0.5 Hz
Frequency Slew Rate1 Hz/sec.
Load Crest Ratio3:1

Safety (pending)

UL 1778 Listed
CUL CAN/CSA C22.2NO.107.1-M91 Listed EN 50091-1
All Cabinets provide seismic mounting features, selectable DC ground fault detection capability

Environmental

Audible Noise

 <75 dBA at 1 meter

Ambient Operating Temperature

 0C to 40C

Ambient Storage Temperature

 -20C to 70C

Altitude5000 ft. (1500 m) at 40C without derating
Relative Humidity

 5-95% non-condensing

EMCMeet FCC Class A, EN 50091-2 (CISPR 22, Class A, Restricted Access)
Electrostatic DischargeWithstands 25kV without damage or disturbance to load
*Specifications subject to change without notice.

Model Selection Guide

 

 9315-750/750

 9315-750/625

  225kVA/180kW

  225kVA/180kW

Input Voltage volts

 480

 600

 480

600

Output Voltage volts

 480

 600

 480

600

Input Voltage Range 

 Minimum volts

 408

 510

 408

510

 Maximum volts

 528

 660

 528

 600

Input/Output Frequency Hz

60

60

 60

 60

AC Input (with input filter)

 Nominal Amps amps

 913

730

 761

609

 Maximum Amps amps

 1141

913

 951

761

Bypass Input 
 Nominal Amps amps

 902

 722

 752

 601

AC Input (without input filter)

 Nominal Amps amps

 902

 722

 752

 601

 10 minutes max amps

 1128

 902

 940

 752

DC Link 

 Nominal DC Voltage volts

 384

384

 384

 384

Float Voltage volts

 432

432

 432

 432

End of Discharge volts

 320

320

 320

 320

Nominal Amps amps

 1954

9554

 1628

 1628

Physical Attributes (w/o batt.) 

Single Module RT Configurations 
 Installed Weight lbs

 13,200

13,200

 13,200

 13,200

 Installed Width inches

 149"

 149"

 149"

 149"

 Multimodule Configurations 
 Installed Weight lbs

 12,600

 12,600

 12,600

 12,600

 Installed Width inches

 126 5/8"

 126 5/8"

 126 5/8"

 126 5/8"

System Efficiencies 

 100% Load %

 94

 94

 94

 94

 75% Load  %

 94

 94

 94

 94

 50% Load  %

 93

 93

 93

 93

Full Load Heat Dissipation 

 BTU/Hr. (x1000) 

130.8

130.8

  109.0

 109.0

 KCal/Hr. (x1000) 

33.0

33.0

 27.5

 27.5

Inverter Efficiency (Full Load)

  %

 95

95

 95

 95

Go to top

Request a PowerWare 9315 PDF Brochure

horizontal rule

Copyright 1999-2003 Powerware Corporation All rights reserved. Legal information Privacy statement

CALL 972-484-8151 or Toll Free 888-566-1615

Email Us at Pro@LEDpowerPRO For Assistance

 

Contact Us   |   About LED Enterprises, Inc.   |   Search   |

Send mail to powerpro@ledpowerpro.com with questions or comments about Power Quality Products, Services, or this web site.
Copyright © 2001 LED Enterprises, Inc.
  Privacy Notice      Conditions of Use